AirTac Fluid Ctrl Valve 2WA Series (Direct Actg. Normally Closed)

Share:


AirTac Fluid Ctrl Valve 2WA Series (Direct Actg. Normally Closed)

 

AirTAC 2WA Series: Stainless Steel Direct Acting Normally Closed (NC) Valve

The AirTAC 2WA Series (Direct Acting) is a precision 2/2-way solenoid valve engineered for the control of high-temperature fluids and steam in smaller piping systems. Built with a 304 Stainless Steel body and high-performance PTFE (Teflon) seals, it is the high-heat counterpart to the standard 2W series.

As a Direct Acting valve, the solenoid force directly moves the internal plunger to open the valve. This eliminates the need for a minimum pressure differential, allowing for a zero-pressure startup—a critical requirement for medical autoclaves, steam sterilization units, and low-pressure high-heat oil systems.

Key Product Features

  • Zero-Pressure Functionality: Operates reliably from 0 MPa (0 psi) up to the maximum rated pressure; ideal for gravity-fed or vacuum-assisted steam applications.

  • High-Temperature Specialized: Rated to handle Steam up to 183°C and hot water or thermal oil up to 150°C.

  • SUS304 Stainless Steel Construction: Provides superior durability and resistance to thermal expansion and corrosion compared to brass.

  • Standard PTFE (Teflon) Seals: Offers universal chemical compatibility and maintains seal integrity under intense heat without becoming brittle.

  • Normally Closed (NC) Logic: Stays shut by default when de-energized, acting as a reliable safety barrier in high-pressure steam environments.

  • Class H High-Heat Coil: Features premium Class H insulation to ensure the electrical components survive the extreme ambient heat radiated by steam lines.


Specifications


Model \ Item Port size [Note 1] Orifice size (ømm) Cv Valid area or section (mm²) Weight [Note 2] (g) Max operating pressure differential Proof pressure
Mpa psi Mpa psi
2WAX030 ­06 1/8" 1.5 0.1 1.8 245 3 450 5 750
­08 1/4" 235
2WAH030 ­06 1/8" 2 0.18 3 245 2 300
­08 1/4" 235
2WA030 ­06 1/8" 3 0.33 6 245 1 150
­08 1/4" 235
2WAL030 ­06 1/8" 4 0.55 10 245 0.5 75
­08 1/4" 235
2WAT030 ­06 1/8" 6 1.1 12 245 0.1 15
­08 1/4" 235
2WAX050 ­06 1/8" 3 0.34 6.1 530 3 450
­08 1/4" 510
2WAH030 ­06 1/8" 4 0.55 10 530 2 300
­08 1/4" 510
2WA050 ­06 1/8" 5 0.83 15 530 1 150
­08 1/4" 510
2WAL050 ­06 1/8" 7 1.4 25 530 0.5 75
­08 1/4" 510
2WAT050 ­06 1/8" 10 2.2 40 530 0.1 15
­08 1/4" 510
Specification of coil 
Valve type Coil type Power type Frequency (Hz) Voltage range Electrical entry Power consumption (VA/W) Insulation Temp.  rise (˚C)
2WA030 CDA 110  CLA 110 AC 50 ±15% Terminal  (CDA)   Grommet (CLA) 10.0VA Class F 50
60 8.0VA 45
DC ±10% 6.5W 50
2WA050 CDA 160   CLA 160 AC 50 ±15% 25.0VA 65
60 22.0VA 60
DC ­- ±10% 12.0W 50
Valve's specification
Acting Direct acting
Initial state Normally closed
Adaptable fluid Air , Water , Oil
Viscosity limit Under 20 CST
Ambient and fluid temperature (˚C)   Water Air Oil Ambient
Max. 80 90 80 70
Min. 1 -­20 [Note 1] ­-10 [Note 2] -­20 






 
 

 Inquiry - AirTac Fluid Ctrl Valve 2WA Series (Direct Actg. Normally Closed)