Specifications
| Model | 200 Series | 300 Series | 400 Series | 600 Series | |
| Orifice size (Cv) mm² | 32 (Cv = 1.8) | 42 (Cv = 2.32) | 69 (Cv = 3.85) | 108 (Cv = 6.0) | |
| Fluid | Air (to be filtered by 40μm filter element) | ||||
| Acting | Internal pilot or external pilot | ||||
| Lubrication [Note 1] | Not required | ||||
| Operating Pressure | Internal pilot | 0.2~1.0MPa(2~10bar) (29~145psi) | |||
| External pilot | 0~1.0MPa (0~10bar) (0~145psi) | 0.2~1.0MPa (2~10bar) (29~145psi) | |||
| Control pressure (External pilot) | 0.2~1.0MPa (2~10bar) (29~145psi) | ||||
| Proof Pressure | 1.5MPa (15bar) (215psi) | ||||
| Temperature | -20~70˚C | ||||
| Port size (Manifold) [Note 2] | 1/4” | 3/8" | 1/2" | 3/4" | |
| Port size (end plate) | 3/8" | 1/2" | 3/4" | 1" | |
| Voltage range | AC ± 15% DC ± 10% | ||||
| Power consumption | AC220V/AC110V:4.5VA AC24V:5.0VA DC24V:3.0W DC12V:2.5W | ||||
| Activating time (0.5MPa) Open\close | 10\20 Series | 33\41ms | 42\55ms | 50\68ms | 55\85ms |
| 30 C\E\ P Series | 38\50ms | 50\62ms | 50\68ms | 55\85ms | |
| Insulation | B Class | ||||
| Protection | IP65 | ||||
| Installation size | ISO5599 - 1 standard | ||||
Inquiry - AirTac ISO Std. Sol. Valve ESV 200-600